• The CM4141-90 is a model that includes both the "CM4141-50" and the "Z3210 Wireless Adapter".
• It can clamp cables with a finished outer diameter of φ55 mm or less. Newly designed slim jaws that easily fit into narrow wiring spaces
- Supports measurements in high-temperature environments and below freezing temperatures, operating temperature range -25℃ to 65℃
- TrueRMS (True RMS) method, ideal for measurements in noisy environments such as around inverter-using equipment
- Complies with CAT IV 600 V and CAT III 1000 V as defined by safety standards
- Simultaneously displays peak value (peak value) and RMS value of starting current (inrush current)
- Compatible with the free app "GENNECT Cross" for managing measurement data on smartphones and tablets (when wireless adapter Z3210 is attached)
[Measurement Items]
AC Current ○, DC Current ×, AC + DC Current ×, AC Voltage ○, DC Voltage ○, AC + DC Voltage ○,
AC Power ×, DC Power ×, Resistance ○, Temperature ○, Capacitance ○, Frequency ○, Continuity Check ○, Diode Check ○
- AC Current (Range) 60.00 A/600.0 A/2000 A, (Accuracy specified range) 1.00 A to 2000 A, (Typical accuracy) ±1.5% rdg ±0.08 A
- AC voltage (range) 6.000 V/60.00 V/600.0 V/1000 V, (Accuracy specified range) 0.000 V to 1000 V, (Typical accuracy) ±0.9% rdg ±0.003 V
- DC voltage (range) 600.0 mV/6.000 V/60.00 V/600.0 V/1000 V, (Accuracy specified range) 0.0 mV to ±1000 V, (Typical accuracy) ±0.5% rdg ±0.5 mV
- DC voltage when using P2000 (sold separately) (range) 600.0 V/2000 V, (Accuracy Range) 80.0 V to ±2000 V, (Typical Accuracy) ±1.0% rdg ±0.3 V
- AC + DC Voltage 6.000 V/60.00 V/600.0 V/1000 V, (Accuracy Range) 0.000 V to 1000 V, (Typical Accuracy) ±1.0% rdg ±0.013 V
- Resistance (Range) 600.0 Ω/6.000 kΩ/60.00 kΩ/600.0 kΩ/6.000 MΩ, (Accuracy Range) 0.0 Ω to 6.000 MΩ, (Typical Accuracy) ±0.7% rdg ±0.5 Ω
- Temperature (Accuracy Range) -40.0℃ to 400.0℃, (Typical Accuracy) ±0.5% rdg ±3.0℃
- Capacitance (Range): 1.000 µF/10.00 µF/100.0 µF/1000 µF, (Accuracy Range): 0.000 µF to 1100 µF, (Typical Accuracy): ±1.9% rdg ±0.005 µF
- Current Frequency (Range): 99.99 Hz/999.9 Hz, (Accuracy Range): 30.00 Hz to 999.9 Hz, (Typical Accuracy): ±0.1% rdg ±0.01 Hz
- Voltage Frequency (Range): 9.999 Hz/99.99 Hz/999.9 Hz, (Accuracy Range): 1.000 Hz to 999.9 Hz, (Typical Accuracy): ±0.1% rdg ±0.003 Hz
[Features]
Automatic AC/DC Detection (Voltage): Yes, Measured Value Display of maximum/minimum/average values (RMS) ○, Display of maximum/minimum values (PEAK) ○, Display of RMS value of inrush current ○, Backlight ○, AUTO power save ○, AUTO range switching ○, Display value hold (automatic*/manual) ○ *The display value is automatically held when the measured value stabilizes.
【Power Supply】
Two AAA alkaline batteries (LR03)
【Continuous Use Time】
Approximately 48 hours (without Z3210), Approximately 24 hours (with Z3210 and wireless communication)
【Dimensions and Weight】
Approximately 65W × 247H × 35D mm, Approximately 300 g (including batteries)
【Accessories】
L9300 Test Leads, C0203 Carrying Case, Two AAA alkaline batteries (LR03), Instruction Manual, Precautions for Use
【Country of Origin】
Japan
【Please Note】 If the seller/distributor is not "Amazon.co.jp", a Japanese instruction manual may not be included.
The CM4141-90 is a model that includes both the "CM4141-50" and the "Z3210 Wireless Adapter".
It can clamp cables with a finished outer diameter of φ55 mm or less.
Suitable for measurements in high-temperature environments and below freezing temperatures, with an operating temperature range of -25℃ to 65℃.
TrueRMS (True RMS Method) is ideal for measurements in noisy environments, such as around inverter-using equipment.